6ES7671-0CC03-0YA0
SIMATIC WINAC BASIS V4.1,

From SIEMENS

SIMATIC WINAC BASIS V4.1, SINGLE LICENSE F. 1 INSTALL., R-SW, SW AND DOCU. ON CD, LICENSE KEY ON FD, CLASS A, 3 LANGUAGES (G,E,F), EXECUTABLE UNDER WIN 2000/XP, REFERENCE-HW: SIMATIC PC
General information
Firmware version4,1
Memory
Work memory
integratedPC RAM can be used
Load memory
integrated RAM, max.PC RAM can be used
CPU processing times
for bit operations, typ.0.013 µs; Typical
for fixed point arithmetic, typ.0.025 µs; Typical
for floating point arithmetic, typ.0.025 µs; Typical
Reference platformPentium 4, 2.4 GHz
CPU-blocks
DB
Number, max.Limited only by available PC work memory
Size, max.64 kbyte
FB
Number, max.Limited only by available PC work memory
Size, max.64 kbyte
FC
Number, max.Limited only by available PC work memory
Size, max.64 kbyte
OB
Size, max.64 kbyte
Number of time alarm OBs1
Number of delay alarm OBs1
Number of cyclic interrupt OBs5
Number of process alarm OBs1
Nesting depth
per priority class24
additional within an error OB24
Counters, timers and their retentivity
S7 counter
Number512
Retentivity
— adjustableYes
— lower limit0
— upper limit511
— preset8
Counting range
— adjustableYes
— lower limit0
— upper limit999
IEC counter
presentYes
TypeSFB
S7 times
Number512
Retentivity
— lower limit0
— upper limit511
— preset0
Time range
— lower limit10 ms
— upper limit9 990 s
IEC timer
presentYes
TypeSFB
Data areas and their retentivity
Retentivity without UPS and PS Extension Boardnone
Retentivity with UPSall data
Flag
Number, max.2 kbyte
of which retentiveMB 0 to MB 2 048
Retentivity presetMB 0 to MB 15
Number of clock memories8
Address area
I/O address area
Inputs16 kbyte
Outputs16 kbyte
Process image
Inputs, adjustable8 kbyte
Outputs, adjustable8 kbyte
Inputs, default512 byte
Outputs, default512 byte
Subprocess images
Number of subprocess images, max.15
Digital channels
Inputs131 072
Outputs131 072
Analog channels
Inputs8 192
Outputs8 192
Hardware configuration
Number of operable FMs and CPs (recommended)
FMFM distributed: FM 350-1 / 350-2, FM 351, FM 352, FM 353, FM 355 / 355-2
CP, PtPCP 340, CP 341 distributed
CP, LANOver PC CP
Submodules
Number of submodules, max4
— of which PROFIBUS, max.4; CP 5611, CP 5611-A2, integrated PROFIBUS interface of the SIMATIC PC, CP 5613 CP, 5613-A2
— of which Industrial Ethernet, max.0
Time of day
Clock
Hardware clock (real-time)Yes
retentive and synchronizableYes
Clock synchronization
supportedNo
1. Interface
Interface typeCP 5611, CP 5611-A2, integrated PROFIBUS interface of the SIMATIC PC
PhysicsRS 485 / PROFIBUS
IsolatedYes
Number of simultaneously operable CPs, max.1
Protocols
MPINo
PROFIBUS DP masterYes
PROFIBUS DP slaveNo
PROFIBUS DP master
Number of connections, max.8
Transmission rate, max.12 Mbit/s
Number of DP slaves, max.32
Services
— PG/OP communicationYes
— RoutingYes
— Global data communicationNo
— S7 basic communicationNo
— S7 communicationYes
— EquidistanceNo
— SYNC/FREEZEYes
— Activation/deactivation of DP slavesYes
— Direct data exchange (slave-to-slave communication)Yes
— DPV0Yes
— DPV1No
Address area
— Inputs, max.16 kbyte
— Outputs, max.16 kbyte
User data per DP slave
— Inputs, max.244 byte
— Outputs, max.244 byte
2. Interface
Interface typeCP 5613, CP 5613-A2
PhysicsRS 485 / PROFIBUS
IsolatedYes
Number of simultaneously operable CPs, max.4
Protocols
MPINo
PROFIBUS DP masterYes
PROFIBUS DP slaveNo
PROFIBUS DP master
Number of connections, max.50
Transmission rate, max.12 Mbit/s
Number of DP slaves, max.125
Services
— PG/OP communicationYes
— RoutingYes
— Global data communicationNo
— S7 basic communicationNo
— S7 communicationYes
— EquidistanceYes
— SYNC/FREEZEYes
— Activation/deactivation of DP slavesYes
— Direct data exchange (slave-to-slave communication)Yes
— DPV0Yes
— DPV1Yes
Address area
— Inputs, max.16 kbyte
— Outputs, max.16 kbyte
User data per DP slave
— Inputs, max.244 byte
— Outputs, max.244 byte
Protocols
Open IE communication
TCP/IPNo
Isochronous mode
Isochronous operation (application synchronized up to terminal)No
Communication functions
PG/OP communicationYes
Global data communication
supportedNo
S7 basic communication
supportedNo
S7 communication
as serverYes
as clientYes
Number of connections
overall64
usable for PG communication
— reserved for PG communication1
usable for OP communication
— reserved for OP communication1
S7 message functions
Number of login stations for message functions, max.64
SCAN procedureNo
Process diagnostic messagesYes; Alarm_S
Alarm 8-blocksNo
Process control messagesNo
Test commissioning functions
Status blockYes
Single stepYes
Status/control
Status/control variableYes
Forcing
ForcingNo
Diagnostic buffer
presentYes
Number of entries, max.
— preset120
Hardware requirement
Hardware requiredPC with color monitor, keyboard, mouse or pointing device for Windows
Processor
ProcessorIntel Pentium 800 MHz
— Multi-processor systemYes; not with CP 5611 or integrated PROFIBUS interface SIMATIC PC
— Hyper-threadingYes; 8 with CP 5611 or integral PROFIBUS interface SIMATIC PC
Memory
Main memory, min.256 Mbyte
Required memory on hard disk100 Mbyte
Operating systems
pre-installed operating system
Windows NT 4.0No
Windows 2000Yes; Professional, SP3 or higher
Windows XPYes; Professional, SP1 and SP2
Configuration
Configuration software
STEP 7Yes; as of V5.2, Engineering Tools (optional)
Programming
Nesting levels8
Programming language
— LADYes
— FBDYes
— STLYes
— SCLYes
— CFCYes
— GRAPHYes
— HiGraph®Yes
Software libraries
— Easy Motion ControlYes
Know-how protection
User program protection/password protectionNo
Open Development interfaces
CCX (Custom Code Extension)Yes; With WinAC ODK V4.1
CMI (Controller Management Interface)Yes; With WinAC ODK V4.1
SMX (Shared Memory Extension)Yes; With WinAC ODK V4.1
— Inputs4 kbyte
— Outputs4 kbyte
last modified:03/13/2019